All pump products want to play a stable performance, it is necessary to properly install according to the corresponding standards, the magnetic drive pump is the same, in order to transport engineering stability and the service life of the pump itself, it is necessary to master the installation precautions of the magnetic pump in advance, although there are some differences in the installation details of different pump types, but the whole is common, see below for details.

As for the installation precautions of magnetic pump, take the conventional horizontal structure magnetic pump as an example, as follows.

1, before installation, check the integrity of the pump body itself, mainly to check the appearance of the pump body and each component, check whether there is deformation, bending and other abnormalities, if there is damage in the process of transportation, need to contact the manufacturer in time, in addition, pay attention to check that the various accessories are complete;

2, according to the transportation conditions to choose the correct installation position, not too high, at the same time to the main environment clean, not close to the wall, need to reserve a certain amount of heat dissipation space;

3. Set a separate support frame for the pipeline, strictly prohibit the direct weight of the pipeline on the pump body, in the pipeline layout, should try to avoid too long and too much bending, in order to prevent unnecessary energy loss;

3, after the completion of installation, check the tightness of each connection, and then carry out the necessary debugging work. First, use a wrench or other tools to manually turn the wheel to ensure that the impeller of the motor rotates flexibly without sticking, and check that each fastener is not loose;

4. Check whether the rotation direction of the motor is consistent with the steering marked by the magnetic pump, and check whether the speed meets the pump type standard;

5. If there is a need to adjust the flow, the motor should be opened first and then the discharge valve should be opened slowly. After the magnetic pump enters the normal running state, the flow can be adjusted by controlling the opening of the discharge valve;

6, stop the magnetic pump before the need to close the discharge valve, and then cut off the power supply, this is to avoid the media backflow.

In summary, a brief introduction to the installation of magnetic pump precautions, overall is not complicated, as long as the basic mechanical knowledge of personnel can be freely installed, if you encounter other problems in the process, you can directly consult saiken pump industry.